Product Description
Product Description
Minimal cost substantial top quality AC900 inverter 220V/380V fifty-60Hz 3 Phase 55kw 75kw VFD with Ce Acceptance
The AC900 collection inverter is a standard large-overall performance recent vector inverter created to manage and regulate the pace of a three-phase asynchronous/induction motor. AC900 adopts substantial-performance vector handle technological innovation, lower speed and high torque output, with very good dynamic attributes and superior overload ability.
AC9004T45GB dimensions of physical appearance and mounting hole :
Model | Mounting Hole | Overall Dimension(mm) | Mounting hole Diameter(mm) | Fat(kg) | ||||
A | B | H | H1 | W | D | |||
AC9004T45GB | 260 | 580 | 549 | 600 | 385 | 265 | Φ10 | 32 |
Wiring Mode of the AC CZPT Manage Circuit:
AC generate | Electrical power capability(kVA) | Enter existing A | Output current A | Adaptable Motor KW. HP |
|
A few-section:380V,50/60HZ | |||||
AC900-4T0.75G | one.five | three.four | 2.one | .75 | one |
AC900-4T1.5G | three. | 5. | 3.eight | 1.five | two |
AC900-4T2.2G | 4. | 5.8 | five.one | two.2 | 3 |
AC900-4T3.0G | five. | eight. | seven. | three. | four |
AC900-4T4.0G | five.nine | ten.five | nine. | 4. | 5 |
AC900-4T5.5G | eight.9 | 14.six | 13. | five.5 | seven.5 |
AC900-4T7.5G | 11. | twenty.five | seventeen. | seven.5 | ten |
AC900-4T11G | 17. | 26. | 25. | 11. | fifteen |
AC900-4T15G | 21. | 35. | 32. | 15. | 20 |
AC900-4T18.5G | 24. | 38.5 | 37. | 18.5 | twenty five |
AC900-4T22G | thirty. | 46.5 | forty five. | 22 | thirty |
AC900-4T30G | forty. | 62. | 60. | thirty | forty |
AC900-4T37G | 57. | 76. | 75. | 37 | fifty |
AC900-4T45G | sixty nine. | ninety two. | 91. | forty five | sixty |
AC900-4T55G | eighty five. | 113. | 112. | fifty five | 70 |
AC900-4T75G | 114. | 157. | 150. | seventy five | one hundred |
AC900-4T90G | 134 | a hundred and eighty | 176 | ninety | a hundred twenty five |
AC900-4T110G | 160 | 214 | 210 | one hundred ten | a hundred and fifty |
AC900-4T132G | 192 | 256 | 253 | 132 | one hundred seventy five |
AC900-4T160G | 231 | 307 | 304 | 160 | 250 |
AC900-4T200G | 250 | 385 | 377 | two hundred | three hundred |
AC900-4T220G | 280 | 430 | 426 | 220 | three hundred |
AC900-4T250G | 355 | 468 | 465 | 250 | four hundred |
AC900-4T280G | 396 | 525 | 520 | 280 | 370 |
AC900-4T315G | 445 | 590 | 585 | 315 | five hundred |
AC900-4T355G | five hundred | 665 | 650 | 355 | 420 |
AC900-4T400G | 565 | 785 | 725 | four hundred | 530 |
Perform description of manage circut terminal:
Type | Terminal | Title | Function Description |
Power CZPT | +10V-GND | External +ten V power source |
Offer +ten V CZPT provide to external unit. Generally, it gives CZPT provide to external potentiometer with resistance assortment of 1-5kΩ. Greatest output present:10mA |
+24V-COM | External +24 V power offer |
Provide +24 V CZPT supply to external unit. Generally, it gives CZPT provide to DI/DO terminals and exterior sensors. Greatest output existing:200mA |
|
Analog Enter | AI1-GND | Analog enter one | Input voltage variety: -ten VDC Impedance: 22kΩ |
AI2-GND | Analog enter two | Input range: -ten VDC/-20mA, decided by jumper J1 on the handle board Impedance: 22kΩ (voltage enter),five hundred Ω (present input) |
|
Digital enter | DI1- COM | Digital input one | Optical coupling isolation Impedance: 2.4kΩ Voltage assortment for level input: 9-30V |
DI2- COM | Digital enter two | ||
DI3- COM | Digital enter three | ||
DI4- COM | Electronic enter four | ||
DI5- COM | Higher-velocity pulse enter |
Aside from attributes of DI1-DI4, it can be utilised for large-velocity pulse input. Optimum enter frequency: 100 kHz |
|
Analog output | AO1-GND | Analog output one | Voltage or current output is determined by jumper J2. Output voltage assortment: -10V Output recent assortment: -20mA |
Digital output | DO1-COM | Digital output one | Optical coupling isolation, twin polarity open up collector output Output voltage variety: -24V Output recent range: -50mA |
FM- COM | Large-speed pulse output |
It is restricted by P5-00 (FM terminal output manner selection). As high-velocity pulse output, the optimum frequency hits a hundred kHz. As open-collector output, its specification is the exact same as that of DO1 |
|
Relay Output | T/A-T/B | NC terminal | Contact driving potential: 250VAC, 3A, COS ø=.four 30VDC, 1A Applying to Overvoltage Group II circuit |
T/A-T/C | NO terminal | ||
Auxiliary interface |
J3 | 485 interaction |
Jumper variety to choose regardless of whether to hook up 330Ω matched resistor to make 485 communication |
J5 | External procedure panel interface |
Join to external procedure panel. |
Application
It is used in dive automation production,involving wire drawing device, movie winding, coating device, CNC machine equipment, weaving devices, jacquard equipment, enthusiasts, pumps, chemical fiber, textile, synchronous conversation, injection molding devices, lifting, elevator, device resources, rolling mills, tube wire processing, lifting, lifting gear, mill.
Packing and shipping and delivery:
Certificate
FAQ
Q:what’s your delivery time?
A:3-5 working times for modest buy, ten-fifteen doing work days for big get.
Q:what is your warranty term?
A:we offer you 24 months guarantee time.
Q:Could you market spare parts?
A if you are employing CZPT product.we can offer spare parts to you.but we could not market the 50 percent-concluded goods.
Q:Can you make the inverter and comfortable starter control board(switchgear)?
A: Indeed,we have a great deal of encounter in layout frequency inverter and soft starter cabinet according to your ask for,these things be created by CZPT selves from CZPT manufacturing unit.
Q:How does your manufacturing unit management the high quality?
A:Good quality is the priority, we constantly connect importance to high quality control from the beginning to the stop of creation,each merchandise will be entirely assembled and carefully examined ahead of packing and shipping and delivery.
Q:how can i CZPT you?
A CZPT business has been audited and accepted ISO9001,CE,CCC,Evaluation report will be sent to you by E mail.And we will get all the responsibility as soon as difficulty for the duration of guarantee time.
Make contact with us:
Two types of AC motors include: Synchronous: The reality that a synchronous motor rotates at the very same charge as the frequency of the mains current presents the motor its name. A synchronous motor is made up of a stator and a rotor. Synchronous motors have a vast assortment of purposes. Induction: Induction motors are the simplest and strongest motors accessible. These AC motors consist of two electrical parts: a wound stator and rotor assembly. The present necessary to switch the rotor is generated by the electromagnetic induction created by the stator windings. Induction motors are a single of the most commonly used varieties of motors in the entire world.