china shop new VFD low voltage power inverter controller AS5004T18P5 manufacturers

Merchandise Description

Item Description

AS500 Series VFD

AS500 sequence large overall performance VFD was adopted with standard V/F control technology, zero-speed sensor vector management technologies, closed loop vector manage and torque handle engineering, as nicely as synchronous open loop vector management engineering and synchronous shut loop vector control technologies, merged with the traits of domestic software, further strengthening the product reliability, environmental adaptability and design for CZPT er and the sector. Products are extensively utilized in weighty business and CZPT machinery load, ideal asynchronous motor and synchronous motor.

Characteristic and Advantages
one. High -successful & vitality conserving procedure

2. CZPT CZPT Reaction
Superior motor handle can also swiftly response to load modify with out PG Card.
3. Sleek monitoring commence
At any time, clean start off can be perfectly attained with out impacting the rotating motor.
four. CZPT ful grid adaptability
Automatic voltage adjustment function: when the grid voltage alterations, the output voltage can be automatically retained constant. In the situation of unexpected reduction of electrical power, unique CZPT -blackout operate can preserve VFD working.
 5. Stable procedure with minimal frequency and higher torque.
Dynamic calcultion of IGBT inside temperature guarantees that the IGBT module operates with the temperture limitations, enhancing reliablity of the module.
six. Constructive-reverse switch
When constructive-reserve motor switch to the zero-speed, the period of recent has no modify or oscillation, and velocity has no ripple.
7. Papid acceleration
.1s complete load acclleration with CZPT torque response and lower velocity overshoot.
eight. IGBT temperature protection curve
Dynamic calculation of IGBT internal temperature assures that the IGBT module operates inside the temperature limites, strengthening railiability of the module.

Intimate software purpose

* PID control committed menu to established PID parameters, determine inside of the VFD, without impartial external regulator option. 

* DC braking before procedure: when the rotating path of motor during free of charge sliding is unsure, DC braking immediately quit the motor before starting up.

* For the sq. torque load of admirer and drinking water pump, higher efficiency excitation management can make the motor operate at the ideal performance stage and attain ideal energy conserving result.

Product Parameters

Power enter Input voltage 380-460V
Input frequency 45-65Hz
Accepting voltage adjust Voltage unbalance <3%
Voltage fall When the 3 period AC380-460V, input voltage <AC300V, low voltage protection was implemented after 15ms.
Power output Voltage 0VAC ~ enter voltage
Overload quality Steady working 40ºC,hefty load 150%, 1min
Effectiveness (complete load) ≥0.ninety four
Output frequency accuracy ±0.01% (digital command -10~+45ºC) ±0.1% (analog command 25±10ºC)
Digital enter/output Optical coupling isolation input 7 channels, 24V high and low stage can be set, enter function can be described
Open up collector output two channels, output operate can be outlined
Relay output 2 channels, generally open up contacts, speak to potential: inductive, 1.5A/250VAC, output operate can be outlined, 2 channels, twin normally open up/shut contacts, get in touch with capability: resistive, 4.5A/250VAC or 4.5A/30VDC inductive: .4A/250VAC or .4A/30VDC, output purpose can be defined
Analog input/output Analog voltage enter two channels, accuracy .1% voltage -10V ~ +10VDC or recent ~20mA optional signal
Analog voltage output 2 channels, accuracy .1% voltage -10V ~ +10VDC or present ~20mA optional signal
Control characteristics Carrier frequency one.1-8KHz CZPT frequency can be altered instantly according to load characters
Frequency setting resolution .01Hz (electronic command), ±0.06HZ/120Hz (analog command 11 bit + no sign)
Operating command channel Given procedure panel, given management terminal, provided conversation
Frequency offered channel Give operation panel, given digital amount/analog amount, given communication, presented overall performance function.
Torque improved Automated torque improved, guide torque improved.
V/F curve User outlined V/F curves, linear V/F curves, and three reduced torque attribute curves
Automatic voltage adjustment (AVR) The responsibility ratio of output PWM sign is adjusted automatically based mostly on the fluctuation of bus voltage, to reduce the influence of grid voltage fluctuation on output voltage fluctuation.
Electric power loss and maintain working procedure In the situation of instantaneous CZPT off, achieve uninterrupted procedure via bus voltage manage
Direct recent braking ability Brake existing: .~a hundred and twenty.% rated recent
Characteristic purpose Parameters duplicate The standard operation panel can add and download parameters and show duplicate process
Procedure PID Employed for closed – loop handle of process quantities
Typical DC bus All sequence can achieve the CZPT provide of frequent DC bus for multiple VFD.
Motor security Rotor block, motor overload, velocity limitation
VFD defense Output existing minimal, VFD overload, IGBT overload, underneath voltage / above voltage of enter CZPT , beneath voltage / in excess of voltage of DC bus, IGBT above heating, CZPT faulty, analog enter sign loss (reduction velocity reference), interaction abnormality, self-tuning faulty.
Atmosphere condition Operation place Mounted vertically in a well-ventilated electrical management cupboard. Horizontal or other installation is not allowed. CZPT medium is air. Put in in setting with no direct sunlight, dust, corrosive gasoline, flammable fuel, oil mist, steam, or h2o.
Surroundings temperature -ten ~ +40 ºC
Utilised in diminished temperature >40 ºC, a increase of 1 ºC, rated output present is reduced by 2%, the optimum temperature is 50ºC
Altitude <1000m
Used in diminished height >1000m, a rise of 1000m, rated output present is reduced by 1% (up to 3000m)
Atmosphere humidity five ~95%, without condensation
Vibration (transport) 2 ≤ f < 9Hz, 3.5 mm 9 ≤f < 200Hz, 10m/s², 200 ≤f < 500Hz, 15m/s²
Vibration (installation) 2 ≤ f < 9Hz, 0.3 mm 9 ≤f < 200Hz, 1m/s²
Storage temperature -40 ~ +70 ºC
Defense quality IP20
Control panel Kind Movable
Duration 1m, 3m
Connector RJ45
Liquid crystal display textual content show four row
LED display 5 bit
Seen LED indicator 4 pcs
essential nine pcs
Others Cooling way Pressure air cooling
Set up manner Mounted in cupboard with wall-mounted
Certificate CE

AS500 collection VFD technological parameters

Stable operating 40ºC, heavy responsibility loading Dimension
VFD Model
AS500
Rated enter recent (A) Rated output present (A) Adaptive motor
(Kw)
Overload one hundred twenty% (1min)
Output existing (A)
4T07P5 20 19 seven.5 28.five A2
4T0011 29 27 11 40.5
4T0115 35 34 fifteen fifty one A3
4T18P5 43 forty one 18.5 sixty one.five
4T0122 fifty 48 22 seventy two
4T0030 66 sixty five thirty 97.5 A4
4T0037 82 eighty 37 120
4T0045 106 96 45 144 A5
4T0055 138 128 fifty five 192
4T0075 170 one hundred sixty 75 240 A6
4T0090 205 195 90 292.five A7
4T0110 250 240 a hundred and ten 360
4T0132 280 270 132 405 A8
4T0160 312 302 160 453
4T0185 380 370 185 555
4T5710 400 390 two hundred 585
4T5710 436 426 220 639
4T5710 490 480 250 720 A9
4T5710 530 520 280 780
4T571 610 600 315 900
4T571 660 650 355 975

Dimension desk

Specification Height(mm) Width (mm) Depth (mm) Weight (kg)
A1 three hundred 160 162 four.5
A2 379 222 182 8
A3 414 232 182 10.three
A4 530 330 288 29.5
A5 610 330 310 38
A6 750 430 350 seventy nine.five
A7 800 430 350 eighty one
A8 880 five hundred 350 112.5
A9 1030 630 370 one hundred seventy
A10 1189 852 431 280
A11 1359 852 431 310

 

Generation line

R&D Centre

 

Screening

 

 

An AC motor is a frequent type of electrical motor that is pushed by alternating present. As the most efficient useful motors for daily industrial apps (as effectively as hobbyist initiatives, house items, and all other professional gear and buyer items), AC motors supply a fairly efficient method of generating mechanical energy from a simple electrical enter signal.
china shop new VFD low voltage power inverter controller AS5004T18P5 manufacturers